Skip to main content

SHRICHMAN — Medical-Grade Laser Equipment & Components

IPL Xenon Flash Lamp — Shrichman
1-Year Warranty on all IPL lamps · CE Approved · Firstlight UK & Heraeus Germany · Ships Worldwide in 3 Days
IPL Parts ✓ In Stock CE Certified Made in UK / Germany

IPL Xenon
Flash Lamp

Premium replacement xenon flash lamps for professional IPL hair removal and skin rejuvenation machines. Supplied by Firstlight (UK) and Heraeus Noblelight (Germany) — two of the world’s most trusted manufacturers of medical-grade high-intensity discharge lamps.

1M
Shot lifetime
12 mo
Warranty
CE ✓
Certified
🛡 12-Month Warranty
✅ CE Approved
📦 Ships in 3 Days
🇬🇧 Firstlight
United Kingdom
Premium clinical-grade lamps. Industry standard for top IPL brands worldwide.
🇩🇪 Heraeus Noblelight
Germany
High-precision German engineering. Preferred for European OEM machine builds.
Price on request — send us your machine brand, model and handpiece for a fast quote
1M
Shot lifetime
2
Premium manufacturers
50+
Lamp models stocked
12 mo
Full warranty
3 days
Ships worldwide
Manufacturers

Two world-class sources — one supplier

We stock lamps from the two most trusted manufacturers of medical-grade IPL xenon flash lamps. Both are CE certified, both are used by the world’s leading IPL machine brands, and both are available from us — so you always get the right lamp for your machine.

🇬🇧
Premium — Industry Standard

Firstlight

United Kingdom

The most widely used xenon flash lamp manufacturer in the professional IPL industry. Firstlight has supplied lamps to the world’s top IPL machine brands for over two decades — when you see a premium IPL machine, there’s a high chance a Firstlight lamp is inside it.

  • Industry gold standard — used in Alma, Cynosure, Lumenis, Syneron machines
  • Tightest spectral consistency and output stability over lifetime
  • 50+ models stocked covering all major handpiece formats
  • Available with wires (standard) and with caps connection
  • Diameters 5mm to 9.3mm, arc lengths 36mm to 195mm
  • CE approved — European medical device standard compliant
🇩🇪
Precision German Engineering

Heraeus Noblelight

Germany

A global leader in specialty light sources for medical, industrial and scientific applications. Heraeus Noblelight’s IPL lamps are manufactured to extremely tight tolerances, with excellent batch-to-batch consistency preferred by European OEM machine manufacturers.

  • German-engineered to ultra-tight manufacturing tolerances
  • Strong preference by European IPL OEM manufacturers
  • Consistent spectral output — ideal for multi-application machines
  • Covers Ellipse, DDD Medtech, Lynton and other European brands
  • CE compliant — ready for EU and UK market distribution
  • Available as direct replacement for selected Firstlight models
Machine Compatibility

Works with the world’s leading IPL machines

Our lamps are the original replacement part used inside these machines. Send us your machine brand and handpiece model — we’ll confirm the exact lamp reference and ship within 3 days.

💡

How to find your lamp

The lamp model number is usually printed on the lamp itself, on the handpiece label, or in the machine service manual. It typically starts with “F1” (Firstlight) or “HL” (Heraeus). If you can’t find it, send us a photo of the handpiece or lamp — we identify it for free.

Alma Lasers

Soprano / Harmony / Accent
  • Soprano Ice / Ice PlatinumF1404 / F1405
  • Soprano XL / TitaniumF1352 / F1556
  • Harmony XL ProF1120 / F1215
  • Accent PrimeF1597
  • ClearLift / ClearSkinF1169

Cynosure / Palomar

Icon / Palomar / Elite
  • Icon MaxYs / MaxGF1245 / F1299
  • Palomar StarLux 500F1224 / F1322
  • Palomar Starlux 300F1185B / F1195
  • Elite IQ / Elite MPXF1442 / F1540
  • Affirm CO₂F1360

Lumenis

LightSheer / M22 / One
  • M22 IPL (all modules)F1119 / F1238
  • One (Universal IPL)F1552
  • LightSheer DesireF1067 / F1352
  • ResurFX / AcuPulseF1106 / F1251
  • Splendor XF1465

Syneron / Candela

eMax / GentleMax / Vela
  • eMax / eLightF1250 / F1314
  • GentleMax ProF1403 / F1404A
  • VelaShape / VelaSmoothF1406
  • Aurora SR / DSF1227 / F1583
  • Galaxy / PolarisF1129 / F1667

Lynton / Ellipse

Excelight / Nordlys / Flex
  • Excelight IPLF1032 / HL series
  • Ellipse NordlysF1543 / HL series
  • Ellipse FlexF1238
  • Lynton LuminaF1019 / F1563
  • Lynton MELAF1652

Fotona / Quanta

SP Dynamis / Q-Plus
  • Fotona SP DynamisF1738 / F1360B
  • Fotona StarWalkerF1540
  • Quanta Q-Plus CF1543
  • Quanta EVOF1543 / F1543
  • Fotona Frac3F1299

Other compatible machines

Cutera Xeo / Excel HR
Sciton BBL Hero
Deka Motus AY
Starvac / Iridex
Venus Versa / Viva
Solta Thermage FLX
Viora Reaction
Pollogen Legend
InMode Diolaze XL
Energist UltraPlus VPL
Bionet IPL-D series
DDD Medtech series
💡
Don’t see your machine? Send us the machine brand, model and a photo of the handpiece or existing lamp — we identify the right Firstlight or Heraeus reference for free. WhatsApp us →
Technical Data

Full technical specifications

Standard parameters for the IPL Xenon Flash Lamp range. Both Firstlight and Heraeus lamps meet or exceed these specifications. Contact us for individual lamp datasheets.

Lamp Identification
Lamp TypeXenon Flash Lamp (High-Pressure Arc Discharge)
ManufacturersFirstlight (UK) · Heraeus Noblelight (Germany)
CertificationCE Approved — European Medical Device Standard
Warranty12 months from shipment — manufacturing defects covered
Physical Dimensions
Available Diameters5 mm · 6 mm · 7 mm · 8 mm · 9 mm · 9.3 mm
Arc Length Range36 mm – 195 mm
Overall Length Range84 mm – 195 mm
Cathode OrientationStandard · 90° (selected models)
Optical & Electrical
Spectral Output Range500 nm – 1200 nm (broadband xenon spectrum)
Envelope MaterialHigh-purity fused silica (quartz)
Fill GasXenon (Xe) — high purity
Connection TypesWith wires (red/black leads) · With caps
Performance & Environment
Shot LifetimeUp to 1,000,000 shots under normal operating conditions
Operating Temperature-20°C to +60°C
StorageCool, dry location — avoid UV exposure and humidity
ApplicationIPL hair removal · Skin rejuvenation · Vascular treatment · Pigmentation
Supply Information
Lead Time3 working days after payment — EXW Shanghai
ShippingWorldwide — DHL / FedEx / air freight
MOQ1 unit (single lamp) — bulk pricing available
OEM / CustomCustom arc lengths and diameters available on request
Lamp Reference Chart

Firstlight & Heraeus lamp reference list

Full stock list. Filter by manufacturer or connection type. All dimensions in mm. Ø = outer diameter · Arc = arc length · OAL = overall length.

Manufacturer: Connection:
ManufacturerModel / ReferenceØ mmArc mmOAL mmConnectionNote
FirstlightF1019 = F1986676136with wires
FirstlightF103283688with wires
FirstlightF10677100167with wires
FirstlightF1106750110with wires
FirstlightF1106A750110with wiresCathode 90°
FirstlightF1119675139 / 165with caps
FirstlightF1120780137with wires
FirstlightF112955195with wires
FirstlightF1169748110with wires
FirstlightF1185B75090with wires
FirstlightF119574790with wires
FirstlightF1215770127with wires
FirstlightF1224960120with wires
FirstlightF1227563111with wires
FirstlightF123866084 / 99with caps
FirstlightF12459.3110195with wires
FirstlightF1250760120with wires
FirstlightF1251750110with wiresCathode 90°
FirstlightF1299890161with wires
FirstlightF1314745135with wires
FirstlightF132295093with wires
FirstlightF13527100167with wires
FirstlightF1352A7100167with wires
FirstlightF1360966120with wires
FirstlightF1360B966120with wires
FirstlightF1403765125with wires
FirstlightF1404750115with wires
FirstlightF1404A750115with wires
FirstlightF1404B750115with wires
FirstlightF1405750115with wires
FirstlightF140655095with wiresCathode 90°
FirstlightF1442790155with wires
FirstlightF14656115175with wires
FirstlightF1540965121with wires
FirstlightF1543845102 / 114with caps
FirstlightF1552670123 / 140with caps
FirstlightF1563 = LL7118690147with wires
FirstlightF15567100167with wires
FirstlightF158355095with wires
FirstlightF1597765130with wires
FirstlightF16525117173with wires
FirstlightF166755087with wires
FirstlightF1738955115with wires
HeraeusNL-7100OEM50110with wiresAlt: F1106
HeraeusNL-7120OEM80137with wiresAlt: F1120
HeraeusNL-7160OEM100167with wiresAlt: F1352
HeraeusNL-6090COEM6099with capsAlt: F1238
HeraeusNL-6140COEM75140with capsAlt: F1119
HeraeusNL-9120OEM60120with wiresAlt: F1224
HeraeusNL-9130OEM66120with wiresAlt: F1360
HeraeusNL-8100COEM45114with capsAlt: F1543
HeraeusNL-5090OEM5095with wiresAlt: F1583
HeraeusNL-7090OEM4590with wiresAlt: F1185B
💡
Cross-reference: Can’t find your exact model? Many Heraeus lamps are direct replacements for Firstlight models. Send us your lamp reference on WhatsApp — we’ll confirm compatibility instantly.
After-Sales

Warranty & support policy

Every lamp we ship carries a 12-month warranty. No call centres — direct support from our IPL engineers.

🛡

12-Month Warranty

Covers manufacturing defects, early output degradation, seal failure and functional failure under normal operating conditions from shipment date.

1,000,000 Shot Guarantee

Every lamp is rated for 1 million flashes. If it fails before that threshold under normal clinic use, we replace it at no charge.

🔧

IPL Engineer Support

Direct access to our IPL engineers for installation guidance, lamp identification, compatibility verification and troubleshooting.

What’s covered

  • Manufacturing defects — cracks, seal failures, burnout before rated lifetime
  • Premature output degradation under normal operating conditions
  • Ignition failure on first installation (Dead on Arrival)
  • Wrong model supplied against a confirmed order
  • Significant spectral output inconsistency from batch specification

What’s not covered

  • Physical damage from improper handling (fingerprints, mechanical stress)
  • Failure due to incompatible machine voltage or trigger settings
  • Lamps that have exceeded their rated shot lifetime
  • Damage from moisture, chemicals or extreme temperature storage
  • Damage from incorrect installation or modified handpiece connections
How to claim warranty: Contact us via WhatsApp or mason@shrichman.com with your order number, description of the issue and photos or video of the failed lamp. We process all claims within 3–5 business days — replacement lamps shipped at no charge for confirmed manufacturing defects.
Important

Safe handling guidelines

High-pressure arc lamps require careful handling. Follow these guidelines to avoid damage before installation and ensure full warranty coverage.

🧤

Always wear gloves

Skin oils contaminate the quartz envelope and cause hot spots during operation, leading to premature failure. Use clean lint-free gloves at all times when handling the lamp body.

👁

Eye protection required

High-pressure xenon lamps can shatter under stress. Wear appropriate eye protection when handling, installing or testing. Never look directly at a firing lamp without IPL eyewear.

🧹

Clean if contaminated

If the lamp glass is touched or contaminated, clean immediately with high-purity methanol (IPA) and a soft lint-free cloth. Allow to dry fully before installation.

⚠️

No stress on the glass

Do not scratch, chip, bend or apply mechanical stress to the quartz envelope. High-pressure arc lamps will fail catastrophically if the envelope integrity is compromised.

📦

Storage conditions

Store in the original packaging in a cool, dry location away from UV sources and humidity. Do not stack objects on top of lamp packaging. Minimum shelf life of 5 years when stored correctly.

🔌

Verify machine settings

Before installation, verify that your machine’s trigger voltage and energy settings are compatible with the lamp specifications. Incorrect settings void warranty and risk premature failure.

Find your lamp —
quote within hours

Send us your machine brand, model, handpiece type or existing lamp reference number. We identify the correct Firstlight or Heraeus lamp, confirm stock and send pricing fast — usually within a few hours during business hours.

Reach us directly — no forms, no waiting:
WhatsApp — Send Lamp Details ✉ Email — Send Requirements
✓ Ships in 3 days ✓ 12-month warranty ✓ CE Certified ✓ Free lamp ID